What is on the display?

Choose the code on the Lay-Z-Spa pump. The line that appears is from the 2025 AirJet manual 303021379874 and the 2025 HydroJet manual 303021371869, for pump models S100202, S200202, S300202 and S400202. A code that is not listed has no meaning here.

Water flow
Temperature
Power and ground
Wi-Fi
My code is not in this list

Choose a code. The manual line and the first check show up here.

E01

The water flow sensors work without pressing the filter or heat button.

Wording in the manual

Do this first: Unplug the pump. The manual says to tap the side of the pump lightly, not hard, then plug it back in, so the sensor flags can drop. Do not open the housing.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E02

The water flow sensors do not detect enough water during the filtering and/or heating functions.

Wording in the manual

Do this first: The manual lists the two stopper caps still inside the spa as a cause. Remove both caps from the inlet and the outlet before you filter or heat, then plug the pump back in.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E03

The pump's thermometer reads the water temperature below 4°C (39°F).

Wording in the manual

Do this first: Unplug the pump. The error table says the spa is not designed to run with water below 4°C (39°F).

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E04

The pump's thermometer reads the water temperature as over 50°C (122°F).

Wording in the manual

Do this first: Unplug now and do not get in. The manual says the spa is not designed for water above 40°C (104°F). Restart only when the water is 38°C (100°F) or cooler.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E05

The pump's thermometer connection has issues.

Wording in the manual

Do this first: Unplug the spa, wait 5 minutes, then plug it back in and switch the pump on. That is the manual's step for this alarm.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E08

The pump's thermometer reads the water temperature as over 52°C (125.6°F).

Wording in the manual

Do this first: Unplug now and do not get in. The manual says the spa is not designed for water above 40°C (104°F). Restart only when the water reaches 38°C (100°F) or lower.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E18

Electricity is detected from the ground wire.

Wording in the manual

Do this first: Unplug the pump and leave it unplugged. The manual says to call an electrician immediately to find out whether power is present on the grounding connection. Do not open the pump.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E19

The power board temperature is too high.

Wording in the manual

Do this first: Unplug the pump and leave it unplugged. The manual's only listed solution is Bestway support. It does not give a button that clears a hot power board. Do not open the housing.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

6CF

Ground connection failed.

Wording in the manual

Do this first: Switch the pump off, remove the plug, and plug it into a different wall socket. The manual says to use a new socket. Plug in directly. The same manuals say not to use an extension cord with the heater.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

E15

Wi-Fi module connection failed.

Wording in the manual

Do this first: Press any button on the panel. The manual says that removes the alarm, and you can keep using the spa without the Wi-Fi connection.

Models this page covers: S100202, S200202, S300202, S400202

Open the full steps

No meaning for that code yet

This page does not invent a meaning. The Lay-Z-Spa list only has the codes quoted from those two 2025 manuals: E01, E02, E03, E04, E05, E08, E15, E18, E19 and 6CF.

Lay-Z-Spa

Questions

What if my code is not in the list?

There is no meaning for it here. A code is published only after it is quoted from the manufacturer manual. The 2025 manuals checked for this page list E01, E02, E03, E04, E05, E08, E15, E18, E19 and 6CF.

The first character looks like a G. Is that 6CF?

The 2025 AirJet and HydroJet manuals print 6CF next to the words Ground connection failed. Choose 6CF. This page does not add a separate GCF code.

Does this cover every Lay-Z-Spa?

No. It covers the codes in the 2025 AirJet manual 303021379874 and the 2025 HydroJet manual 303021371869, for pump models S100202, S200202, S300202 and S400202. A 2020 manual states the cold and hot alarms differently.