Control system

Balboa error codes

These messages are quoted from Balboa Water Group user guide 40985-G, dated 26 March 2014. It covers system models BP2500 and BP2600, software 5.0 and later, with a TP900 panel (software 2.0 or later) or a TP800 panel (software 1.9 or later). The guide calls the numbers Message Codes, such as M016. It does not print the short letters dr, Pr, or EC, so those letters are not given a meaning here. A message with no M-code in this guide is not a separate page.

Code

Code What it means
M016 Water flow through the heater is low
M017 Heater flow failed and the heater is off
M028 The heater may be dry
M027 The heater is dry and the spa is shut down
M030 A heater sensor reads 118°f and the spa is off
M029 Spa water is 110°F or hotter
M015 Sensors may differ by 2°F or 3°F
M026 Sensors are out of sync for at least an hour
M031 Sensor A or its circuit has failed
M032 Sensor B or its circuit has failed
M022 The program checksum failed at power-up
M020 The clock has failed
M021 Settings were reset after a memory error
M036 The system could not test the GFCI
M035 A pump was stuck on at the last power-up
M034 A pump may be stuck on and the water overheated